Ptfe Pfa Dual Plate Wafer Lined Check Valve

Place of Origin:
Wenzhou,China
Packing:
Suitable Packing for Sea/Air Transport
Connection:
Wafer Type
Pressure:
PN10,PN16,150LBS
Temperature:
PTFE:-29℃ ~180℃, PFA:-29℃~200℃, FEP:-29℃~150℃

A lined check valve prevents backflow across aggressive piping networks through twin semicircular plates that swing shut on a central hinge pin. Resilient springs accelerate closure before fluid velocity reverses, eliminating destructive hydraulic shock while delivering bubble-tight isolation against strong mineral acids without metallic exposure.

Fluoropolymer Liner Anchorage and Vacuum Stability Under Acid Exposure

Piping systems handling hot hydrochloric or fuming nitric solutions require a ptfe lined check valve engineered with compression-molded polymer barriers.

Virgin fluoropolymers resist severe chemical corrosion across broad temperature boundaries, yet continuous mechanical stress can cause cold flow displacement. Machining dovetail retention grooves inside ductile iron casings locks the fluoroplastic lining securely against the outer shell. This mechanical anchorage prevents liner collapse during negative pressure transients and full vacuum operations up to 180°C.

Severe Service Non-Return Valve Architecture Matrix

Mechanical Profile Body Installation Style Shutoff Response Speed Intended Chemical Environment
Dual Spring Plates Wafer Flange Clamped Milliseconds Dynamic High velocity corrosive pump outlets
Guided Solid Disc Flanged Inline Body Standard Gravity Reset Vertical upward acid transfer lines
Free Floating Ball Flanged Full Port Moderate Gravity Sinking Corrosive slurries with particulates

Matching line hydraulic dynamics with internal closure mechanics prevents plate flutter and seat damage.

Water Hammer Suppression and Compact Wafer Spool Installation

Selecting a traditional lined swing check valve introduces engineering challenges inside congested piperacks due to elongated face-to-face body dimensions.

Swing designs rely on a single heavy flapper swinging across ninety degrees, creating delayed closure during sudden pump shutdown. A dual plate wafer construction halves disc travel distance, allowing spring tension to seat both plates immediately upon flow deceleration. This compact geometry minimizes pipe support requirements while shielding fragile fluoropolymer-lined conduits from sudden surge pressures.

Melt Processed Permeation Barriers and Bolt Torque Assembly Protocols

Transferring ultra-pure chemical mixtures or halogen compounds demands a pfa lined check valve featuring melt-processed fluoropolymer linings. Transfer molding produces uniform wall density around internal body recesses and hinge retainers, eliminating microscopic voids that permit acidic vapor permeation into pressure-retaining casings.

Technicians install wafer bodies between companion flanges using calibrated torque wrenches in progressive crisscross sequences. Uniform bolt loading prevents uneven compression across raised sealing faces, stopping localized cold flow leaks. Maintaining sufficient upstream straight pipe diameters suppresses turbulent eddies, eliminating cavitation erosion across severe chemical processing installations.

Product Parameter

Materials of Main Parts

No. Part Name Material List
1 Body/Bonnet HT250 WCB CF8 CF8M CF3 CF3M
2 Disc/Stem 25                                           1Cr18Ni19/CF8                            00Cr17Ni14Mo2/CF3M
3 Lining/Seat PCTFE(F3)          FEP(F46)          PTFE(F4)          PFA          PO
4 Bolt 35 35 0Cr18Ni9 0Cr18Ni9 0Cr18Ni9 0Cr18Ni9
5 Nut 45 45 0Cr18Ni9 0Cr18Ni9 0Cr18Ni9 0Cr18Ni9

Technical Specification

Design & Manufacture Standard GB/T 12236 API 6D
Face-to-face Dimension Standard GB/T 12221 ASME B16.10
Flange Standard HG/T 20592 ASME B16.5
Inspection and Test Standard GB/T 13927 API 598
Nominal Pressure 1.0MPa 1.6Mpa 150LB
Test Pressure Shell Test 1.5MPa 1.5MPa 1.5MPa
High Pressure Sealing 1.1MPa 1.1MPa 1.1MPa
Low Pressure Sealing 0.6MPa 0.6MPa 0.6MPa
Temperature Range PFA:-29℃~200℃    PTFE:-29℃~180℃  FEP:-29℃~150℃
Applicable Medium Strong corrosive medium i.e.hydrochloric acid,Nitric acid,Hydrofluoric acid,Liquid chlorine,Sulfuric acid and Aqua regia etc.
Note:Test standard refers to general valve standard,high pressure should be customized for processing.