Ptfe Pfa Vertical Lift Lined Check Valve
- Place of Origin:
- Wenzhou,China
- Packing:
- Suitable Packing for Sea/Air Transport
- Connection:
- Flange
- Pressure:
- PN10,PN16,150LBS
- Temperature:
- PTFE:-29℃ ~180℃, PFA:-29℃~200℃, FEP:-29℃~150℃
A lined check valve prevents fluid backflow within vertical riser conduits when upward process pressure lifts an encapsulated internal poppet along a centered vertical axis. Diminishing flow rates allow gravitational mass and line backpressure to seat the poppet against the perimeter orifice instantaneously, preventing reverse contamination and shielding pump impellers against severe hydrodynamic shock.
Polymer Cold Flow Suppression and Negative Pressure Interlocking
Chemical distribution systems handling concentrated hydrochloric acid or pickling solutions utilize a ptfe lined check valve to withstand corrosive erosion up to 180°C. Pure fluoroplastics deliver complete chemical passivity, though continuous mechanical compression risks structural cold flow.
Machining precise dovetail locking recesses along ductile iron body interiors anchors the fluoropolymer lining securely. This mechanical anchorage prevents polymer collapse during unexpected line drainage, pipe siphonage, or total vacuum conditions.
Industrial Vertical Pipeline Flow Restrictor Selection Parameters
| Internal Shutter Geometry | Spool Mounting Plane | Leakage Class Rating | Process Fluid Service |
|---|---|---|---|
| Center Guided Solid Poppet | Vertical Upward Axis | API 598 Bubble-Tight | Aggressive inorganic chemicals |
| Perimeter Hinged Gate | Horizontal Axis Only | ISO 5208 Rate A | High volume acid feedstocks |
| Spring Balanced Retainer | Universal Mounting | MSS SP-72 Class VI | Pulsating reciprocating pump runs |
Matching line alignment with closure mechanisms suppresses internal turbulence and prolongs seat integrity.
Axial Poppet Stability and Hydrodynamic Shock Attenuation
Inspecting a lined ball check valve exposes design challenges inside vertical pump discharge lines where high velocity fluids induce unconstrained balls to spin erratically. Spherical rotation causes lateral seat gouging, fluid chattering, and delayed closure during sudden pump shutdown.
A vertical lift architecture incorporates rigid alignment guides that constrain poppet travel strictly along the pipe centerline. Linear travel stabilizes discharge fluid streams, eliminates rattling friction, and cushions fluid hammer during abrupt pressure transitions.
Melt Processed Permeation Barriers and Stud Tensioning Procedures
Severe chemical processes transferring fuming acids or chlorine compounds operate reliably using a pfa lined check valve manufactured via transfer molding. Molten resin processing produces dense, void-free barriers that stop gaseous chemical migration through the fluoroplastic matrix into outer cast shells.
Technicians install flanged connections using calibrated torque wrenches in progressive crisscross sequences. Balanced bolt tension prevents localized flange face crushing, preserving raised sealing perimeters throughout continuous industrial campaigns.
Product Parameter
Materials of Main Parts
| No. | Part Name | Material List | |||||
| 1 | Body/Bonnet | HT250 | WCB | CF8 | CF8M | CF3 | CF3M |
| 2 | Disc/Stem | 25 1Cr18Ni19/CF8 00Cr17Ni14Mo2/CF3M | |||||
| 3 | Lining/Seat | PCTFE(F3) FEP(F46) PTFE(F4) PFA PO | |||||
| 4 | Bolt | 35 | 35 | 0Cr18Ni9 | 0Cr18Ni9 | 0Cr18Ni9 | 0Cr18Ni9 |
| 5 | Nut | 45 | 45 | 0Cr18Ni9 | 0Cr18Ni9 | 0Cr18Ni9 | 0Cr18Ni9 |
Technical Specification
| Design & Manufacture Standard | GB/T 12236 | API 6D | ||
| Face-to-face Dimension Standard | GB/T 12221 | ASME B16.10 | ||
| Flange Standard | HG/T 20592 | ASME B16.5 | ||
| Inspection and Test Standard | GB/T 13927 | API 598 | ||
| Nominal Pressure | 1.0MPa | 1.6Mpa | 150LB | |
| Test Pressure | Shell Test | 1.5MPa | 1.5MPa | 1.5MPa |
| High Pressure Sealing | 1.1MPa | 1.1MPa | 1.1MPa | |
| Low Pressure Sealing | 0.6MPa | 0.6MPa | 0.6MPa | |
| Temperature Range | PFA:-29℃~200℃ PTFE:-29℃~180℃ FEP:-29℃~150℃ | |||
| Applicable Medium | Strong corrosive medium i.e.hydrochloric acid,Nitric acid,Hydrofluoric acid,Liquid chlorine,Sulfuric acid and Aqua regia etc. | |||
| Note:Test standard refers to general valve standard,high pressure should be customized for processing. | ||||
Get A Quote