Ptfe Pfa Teflon Wafer Lined Check Valve
- Place of Origin:
- Wenzhou,China
- Packing:
- Suitable Packing for Sea/Air Transport
- Connection:
- Wafer Type
- Pressure:
- PN10,PN16,150LBS
- Temperature:
- PTFE:-29℃ ~180℃, PFA:-29℃~200℃, FEP:-29℃~150℃
A lined check valve prevents process backflow within compact pipeline runs when forward fluid pressure pushes an encapsulated disc off its fluoropolymer seating face. Diminishing upstream line pressure allows system backpressure to seat the closure element instantaneously, preventing fluid inversion and shielding pump impellers against hydraulic surge pressures.
Dovetail Anchorage and Mechanical Vacuum Integrity
Corrosive handling across concentrated mineral acids requires a ptfe lined check valve engineered with compression-molded resin liners. Pure fluoroplastics provide comprehensive chemical inertness, yet operational thermal fluctuations risk cold flow displacement.
Machining interlocking dovetail grooves into ductile iron body castings locks the fluoropolymer barrier securely. This mechanical anchorage prevents liner separation during negative pressure transients and full vacuum processing conditions up to 180°C.
Severe Service Non-Return Configuration Mechanical Comparison
| Internal Closure Design | Pipeline Spool Alignment | Testing Certification | Targeted Fluid Environment |
|---|---|---|---|
| Center Guided Wafer Disc | Horizontal or Vertical Up | API 598 Zero Bubble Leak | Concentrated inorganic acids |
| Free Guided Gravity Ball | Strict Vertical Upward | ISO 5208 Rate A Seal | Acid slurries with entrained solids |
| Hinged Dynamic Flapper | Horizontal Line Run | DIN EN 12266-1 Tightness | High volume bulk chemical transfer |
Matching pipe orientation with internal fluid forces suppresses mechanical vibration and prolongs sealing face longevity.
Disc Chattering Suppression and Hydraulic Shock Dissipation
Evaluating a teflon lined check valve shows clear operational advantages over free-floating spherical designs inside horizontal conduits. Ball assemblies require continuous fluid velocities to avoid erratic hovering, causing line chattering during fluctuating flow outputs.
The wafer configuration maintains constrained disc movement along its center axis. This constrained guidance dampens hydrodynamic turbulence, reduces seat wear, and eliminates mechanical slamming during unexpected line depressurization.
Melt Processed Barrier Uniformity and Flange Torque Distribution
Demanding chemical services transfer hot halogenated solvents utilizing pfa lined check valves with transfer-molded fluoropolymer shields. Melt processing achieves high molecular cohesion, eliminating microscopic pinholes that permit acid vapors to penetrate metallic shell boundaries.
Technicians install wafer bodies between raised face companion flanges using calibrated torque wrenches in cross-pattern sequences. Uniform bolt tensioning prevents localized plastic deformation along sealing perimeters. Maintaining five straight pipe diameters upstream eliminates boundary layer swirl, preserving seating surfaces throughout continuous operation.
Product Parameter
Materials of Main Parts
| No. | Part Name | Material List | |||||
| 1 | Body/Bonnet | HT250 | WCB | CF8 | CF8M | CF3 | CF3M |
| 2 | Disc/Stem | 25 1Cr18Ni19/CF8 00Cr17Ni14Mo2/CF3M | |||||
| 3 | Lining/Seat | PCTFE(F3) FEP(F46) PTFE(F4) PFA PO | |||||
| 4 | Bolt | 35 | 35 | 0Cr18Ni9 | 0Cr18Ni9 | 0Cr18Ni9 | 0Cr18Ni9 |
| 5 | Nut | 45 | 45 | 0Cr18Ni9 | 0Cr18Ni9 | 0Cr18Ni9 | 0Cr18Ni9 |
Technical Specification
| Design & Manufacture Standard | GB/T 12236 | API 6D | ||
| Face-to-face Dimension Standard | GB/T 12221 | ASME B16.10 | ||
| Flange Standard | HG/T 20592 | ASME B16.5 | ||
| Inspection and Test Standard | GB/T 13927 | API 598 | ||
| Nominal Pressure | 1.0MPa | 1.6Mpa | 150LB | |
| Test Pressure | Shell Test | 1.5MPa | 1.5MPa | 1.5MPa |
| High Pressure Sealing | 1.1MPa | 1.1MPa | 1.1MPa | |
| Low Pressure Sealing | 0.6MPa | 0.6MPa | 0.6MPa | |
| Temperature Range | PFA:-29℃~200℃ PTFE:-29℃~180℃ FEP:-29℃~150℃ | |||
| Applicable Medium | Strong corrosive medium i.e.hydrochloric acid,Nitric acid,Hydrofluoric acid,Liquid chlorine,Sulfuric acid and Aqua regia etc. | |||
| Note:Test standard refers to general valve standard,high pressure should be customized for processing. | ||||
Get A Quote
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.