Pfa Lined Teflon Globe Control Valve

Place of Origin:
Wenzhou,China
Packing:
Suitable Packing for Sea/Air Transport
Connection:
Flange
Pressure:
PN10,PN16,150LBS
Temperature:
-29℃ ~180℃

A lined control valve achieves zero external leakage through complete chemical isolation, separating aggressive line media from metallic bonnets through an impermeable polymeric barrier and continuous stem containment. Virgin fluoropolymer wetted components withstand severe hydrochloric acid, chlorine gas, and spent acid streams, preventing metal corrosion and atmospheric contamination. This sealed construction maintains stable fluid throttling without atmospheric vapor loss across continuous operating cycles.

Bellows Hermetic Isolation And Dynamic Stroke Endurance

Standard elastomeric stem seals degrade under aggressive chemical exposure, forming dangerous fugitive emission pathways along sliding valve stems. Precision compression molding forms uniform bellows convolutions capable of absorbing tens of thousands of mechanical cycles without tensile fatigue failure.

Internal anti-torsion guides shield delicate convolutions against rotational stress induced through pneumatic actuator thrust. Installing lined control valves equipped with multi-ply fluoropolymer bellows assemblies guarantees hermetic stem isolation across fluctuating operating pressures, preventing toxic vapor escape during rapid throttling strokes.

Stem Sealing Configuration And Fugitive Emission Thresholds

Sealing Configuration Fugitive Emission Rating Test Medium Protocol Design Mechanical Endurance
Standard Chevron Rings ISO 15848-1 Class CH Methane tracer detection 20,000 continuous full strokes
Reinforced Live-Loaded Rings ISO 15848-1 Class BH Helium vacuum sniffing 50,000 continuous full strokes
Hermetic Polymer Bellows ISO 15848-1 Class AH Helium mass spectrometry 100,000 continuous full strokes

Halogen Permeation Mitigation In High Temperature Loops

Elevated processing temperatures generate severe chemical vapor gradients that force volatile acid molecules through low-density polymer linings. Specifying a pfa lined control valve suppresses molecular diffusion through high-density resin compounding, eliminating micro-void formation and blistering across elevated operating temperatures reaching two hundred degrees Celsius.

Uniform wall thickness prevents localized wall thinning along tight internal turns. This dense barrier maintains environmental compliance across continuous chemical processing campaigns.

Redundant Packing Containment And Pneumatic Regulation

Severe line disruptions require secondary safety containment behind primary barriers. A secondary adjustable PTFE packing gland captures volatile vapors if primary bellows assemblies suffer over-pressurization.

Integrating a teflon lined globe control valve provides streamlined internal flow paths that lower turbulence around sensitive seating zones. Precision pneumatic diaphragm actuators direct calibrated positioning force straight down the valve stem, minimizing side thrust and maximizing sealing longevity across automated processing units.

Product Parameter

Materials of Main Parts

No. Part Name Material List
1 Body/Bonnet WCB CF8 CF8M CF3 CF3M
2 Disc/Stem 1Cr13 1Cr18Ni9 00Cr17Ni4Mo2 1Cr18Ni9 00Cr17Ni4Mo2
3 Lining/Seat FEP     PTFE      PFA      PO
4 Packing PTFE
5 Packing Gland WCB CF8 CF8M CF3 CF3M

Technical Specification

Seat diameter (mm) 20 25 25 32 32 40 40 50 50 65 65 80 80 100 100 110 125 150 175
Rated Cv 5 10 10 16 16 24 24 44 44 68 68 125 125 165 165 195 330 360 460
Rated travel 16mm 25mm 38mm 50mm 60mm
Actual pressure Maxmum 1.0 MPa (1.6 MPa customised)
Nominal pressure I.0MPa, 1.6MPa
Working temperature -29°C-180°C
Trim Single seat plunger valve core
Flow characteristic Linear, equal percentage
Adjustable range 50:1
Equipped with ZJHA/B Multi-springs Diaphragm Pneumatic Actuators
Model ZJHA/B-22 ZJHA/B-23 ZJHA/B-34 ZJHA/B-45
Action mode ZJHA type actuator refer to "air-to-close" action: ZJHB actuator refer to "air-to-open" action
Pressure supply According to the scope of spring: 0.02-0.10, 0.04-0.20, 0.08-0.24 Mpa. Respectly are 0.14, 0.25, 0.35 MPa
Air supply connection Rc1/4
Basic error Without positioner:±5%; With posilioner:±1%;
Backlash Without positioner: 3%; With positioner: 1%;
Dead zone Without positioner: 3%; With positioner: 0.4%;
End point deviation Without positioner: opening point±2.5%, terminal point±5%;closing point±5%, terminal point±2.5%. With positioner error from beginning to end is ±1%;
Travel deviation ±2.5%
Leakage rate No more than 10 of rated CV
Optional accessories positioner, air set, solenoid valve, limit switch etc. (according to the order)