Actuated Fep Ptfe Pfa Lined Globe Valves
- Place of Origin:
- Wenzhou,China
- Packing:
- Suitable Packing for Sea/Air Transport
- Connection:
- Flange
- Pressure:
- PN10,PN16,150LBS
- Temperature:
- PTFE:-29℃ ~180℃, PFA:-29℃~200℃, FEP:-29℃~150℃
A lined globe valve delivers automated isolation across corrosive chemical processes without requiring site pneumatic distribution systems. Driven through integrated electric motor assemblies paired with seamless fluorinated ethylene propylene linings, this linear valve architecture executes ANSI FCI 70-2 Class VI bubble-tight shutoff across hydrochloric acid, sodium hypochlorite, and pickling liquors. Chemical manufacturing facilities install these motorized units to secure continuous proportional dosing while shielding external metal housings from fluid degradation.
Surface Smoothness and Actuator Load Reduction
Fluid friction and mineral scaling impose excessive operating drag against linear valve plugs during frequent cycling.
In high-purity chemical distribution headers, a ptfe lined globe valve utilizes smooth internal boundary layers to prevent particulate clinging across high-velocity throttling zones. The ultra-low friction coefficient of melt-processable fluoropolymers minimizes mechanical resistance along the rising stem shaft, permitting the electric motor drive to seat the closure assembly using lower electrical wattage without risking mechanical stall.
FEP Lining Uniformity and Motorized Actuation Specifications
| Nominal Piping Size | Minimum Fluoropolymer Depth | Spark Testing Voltage | Full Travel Operating Period |
|---|---|---|---|
| DN25 (1 Inch NPS) | 3.0 mm | 14 kV | 12 seconds |
| DN50 (2 Inch NPS) | 3.5 mm | 14 kV | 16 seconds |
| DN80 (3 Inch NPS) | 4.0 mm | 16 kV | 22 seconds |
| DN100 (4 Inch NPS) | 4.5 mm | 16 kV | 28 seconds |
Melt-Processable Density and Sub-Micron Permeation Resistance
Microscopic porosity within traditional paste-extruded resins creates pathways for acid molecule migration toward outer castings. When handling aggressive halogen compounds, a pfa lined globe valve incorporates injection-molded linings that fuse seamlessly into dovetail grooves anchored within ductile iron casings.
This melt-flow processing eliminates pin-hole defects across complex interior radii, preventing subsurface separation under severe vacuum conditions. Solid non-porous polymer walls restrict corrosive penetration, preserving casing strength across demanding chemical synthesis operations.
Solid-State Modulating Calibration and Mechanical Seat Safeguards
Accurate reagent neutralization requires incremental plug movement without positioner overshoot. Equipping pfa lined globe valves with digital micro-stepping electric actuators resolves incoming 4-20mA control signals into fractions of a millimeter of stem travel.
Internal electronic load sensors arrest electric motor operation immediately upon reaching calibrated compressive seating limits, eliminating mechanical pinching stress across virgin sealing faces while preventing fugitive atmospheric emissions throughout extended production campaigns.
Product Parameter
Materials of Main Parts
| No. | Part Name | Material List | ||
| 1 | Body/Bonnet | HT250 | WCB | CF8 |
| 2 | Disc/Stem | 35 | 1Cr13 | 1Cr18Ni19 |
| 3 | Lining/Seat | PCTFE(F3) PTFE(F4) FEP(F46) PFA PO | ||
| 4 | Packing | PTFE(F4) | ||
| 5 | Packing Gland | WCB | WCB | CF8 |
| 6 | Handwheel | HT200 | HT200 | WCC |
Technical Specification
| Design & Manufacture Standard | GB/T 12233 | BS 5160 | ||
| Face-to-face Dimension Standard | GB/T 12221 | BS 5160 | ||
| Flange Standard | HG/T 20592 | ASME B16.5 | ||
| Inspection and Test Standard | GB/T 13927 | API 598 | ||
| Nominal Pressure | 1.0MPa | 1.6Mpa | 150LB | |
| Test Pressure | Shell Test | 1.5MPa | 1.5MPa | 1.5MPa |
| High Pressure Sealing | 1.1MPa | 1.1MPa | 1.1MPa | |
| Low Pressure Sealing | 0.6MPa | 0.6MPa | 0.6MPa | |
| Temperature Range | PFA:-29℃~200℃ PTFE:-29℃~180℃ FEP:-29℃~150℃ | |||
| Applicable Medium | Strong corrosive medium i.e.hydrochloric acid,Nitric acid,Hydrofluoric acid,Liquid chlorine,Sulfuric acid and Aqua regia etc. | |||
| Note:Test standard refers to general valve standard,high pressure should be customized for processing. | ||||