Electric Ptfe Pfa Lined Globe Valves
- Place of Origin:
- Wenzhou,China
- Packing:
- Suitable Packing for Sea/Air Transport
- Connection:
- Flange
- Pressure:
- PN10,PN16,150LBS
- Temperature:
- PTFE:-29℃ ~180℃, PFA:-29℃~200℃, FEP:-29℃~150℃
A lined globe valve regulates hazardous chemical lines through motorized multi-turn or linear electric actuation, isolating pressure-retaining ductile iron castings from aggressive media exposure. Operating with integrated microprocessor positioners and non-intrusive electronic control units, this motorized valve architecture executes ANSI FCI 70-2 Class VI bubble-tight shutoff across hydrochloric, nitric, and hydrofluoric acid circuits. Remote processing installations deploy these self-contained assemblies to secure precise automated chemical dosing where compressed plant air headers remain unavailable.
Electronic Torque Sensing and Polymer Seat Preservation
Excessive mechanical downward force risks permanently crushing internal fluoropolymer geometries during shutoff sequences.
In pressurized acid mixing loops, a ptfe lined globe valve utilizes internal electronic load sensors that continuously monitor motor current draw against calibrated resistance profiles. When the plug engages the stationary seating orifice, the electronic governor interrupts motor power within milliseconds, ensuring optimal compressive seating stress without inducing localized plastic deformation across repeated cycling.
Linear Electric Actuator Mechanics and Operating Specifications
| Nominal Valve Size | Linear Output Thrust | Operating Stroke Speed | Motor Power Consumption |
|---|---|---|---|
| DN25 (1 Inch NPS) | 2.5 kN | 1.2 mm per second | 45 Watts |
| DN50 (2 Inch NPS) | 5.0 kN | 1.2 mm per second | 65 Watts |
| DN80 (3 Inch NPS) | 9.0 kN | 0.9 mm per second | 90 Watts |
| DN100 (4 Inch NPS) | 14.0 kN | 0.9 mm per second | 120 Watts |
Microprocessor Positioning and Modulating Accuracy
Continuous titration processes demand tight setpoint tracking without persistent hunting or positioning drift. When regulating variable chemical volumes, a pfa lined globe valve incorporates digital positioners responding to standard 4-20mA instrumentation loops.
Solid-state circuitry converts incoming analog control values into high-resolution stepping increments, suppressing deadband drift across fractional plug displacements. Seamless perfluoroalkoxy trims maintain smooth hydraulic contours through high-velocity passages, securing repeatable process yields across intense chemical processing runs.
Live-Loaded Stem Sealing and Thermal Dissipation Dynamics
Motorized linear movement generates localized friction heat along the reciprocating stem boundary. Equipping pfa lined globe valves with multi-ring fluoropolymer chevron sets energized through stacked Belleville washers maintains uniform radial compression around the polished shaft.
This dynamic live-loaded assembly absorbs alternating thermal expansion forces between polymer elements and metallic pillars, preventing stem binding and arresting fugitive atmospheric emissions across continuous industrial campaigns.
Product Parameter
Materials of Main Parts
| No. | Part Name | Material List | ||
| 1 | Body/Bonnet | HT250 | WCB | CF8 |
| 2 | Disc/Stem | 35 | 1Cr13 | 1Cr18Ni19 |
| 3 | Lining/Seat | PCTFE(F3) PTFE(F4) FEP(F46) PFA PO | ||
| 4 | Packing | PTFE(F4) | ||
| 5 | Packing Gland | WCB | WCB | CF8 |
| 6 | Handwheel | HT200 | HT200 | WCC |
Technical Specification
| Design & Manufacture Standard | GB/T 12233 | BS 5160 | ||
| Face-to-face Dimension Standard | GB/T 12221 | BS 5160 | ||
| Flange Standard | HG/T 20592 | ASME B16.5 | ||
| Inspection and Test Standard | GB/T 13927 | API 598 | ||
| Nominal Pressure | 1.0MPa | 1.6Mpa | 150LB | |
| Test Pressure | Shell Test | 1.5MPa | 1.5MPa | 1.5MPa |
| High Pressure Sealing | 1.1MPa | 1.1MPa | 1.1MPa | |
| Low Pressure Sealing | 0.6MPa | 0.6MPa | 0.6MPa | |
| Temperature Range | PFA:-29℃~200℃ PTFE:-29℃~180℃ FEP:-29℃~150℃ | |||
| Applicable Medium | Strong corrosive medium i.e.hydrochloric acid,Nitric acid,Hydrofluoric acid,Liquid chlorine,Sulfuric acid and Aqua regia etc. | |||
| Note:Test standard refers to general valve standard,high pressure should be customized for processing. | ||||
Get A Quote
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.