Ptfe-lined Gate Valve Design Features And Advantages
- Place of Origin:
- Wenzhou,China
- Packing:
- Suitable Packing for Sea/Air Transport
- Connection:
- Flange
- Pressure:
- PN10,PN16,150LBS
- Temperature:
- PTFE:-29℃ ~180℃, PFA:-29℃~200℃, FEP:-29℃~150℃
PTFE lined globe valve is designed for chemical and petrochemical pipelines where corrosive media require both shutoff and flow adjustment. The PTFE lining isolates aggressive fluids from metal components, while the globe valve structure provides controlled throttling performance. It is suitable for acids, solvents, alkalis, and other chemical fluids that may damage standard valves.
Why Corrosive Media Challenges Valve Control
Chemical pipelines often require valves to stop flow and adjust operating conditions. Traditional metal valves may face corrosion, leakage, and sealing problems when exposed to aggressive chemicals.
Common issues include:
- Chemical corrosion of internal surfaces
- Leakage caused by sealing damage
- Reduced flow adjustment accuracy
- Frequent maintenance caused by corrosion
A suitable lined globe valve creates a protective barrier while maintaining stable flow control.
What Is a PTFE Lined Globe Valve?
A PTFE lined globe valve uses PTFE fluoropolymer lining inside the valve body and flow passage. The lining prevents direct contact between chemical media and metal surfaces while maintaining structural strength.
Main design features include:
- PTFE lining for chemical resistance
- Globe valve structure for precise adjustment
- Corrosion-resistant internal passage
- Reliable sealing performance
This structure allows the valve to handle corrosive fluids while supporting both isolation and regulation.
How Lined Globe Valves Manage Corrosive Fluids
The main function of a lined globe valve is to control fluid movement while reducing chemical damage to valve components. The disc and seat design allow gradual flow adjustment.
Main benefits include:
- Chemical protection
PTFE lining resists many acids, solvents, and alkaline fluids.
- Flow regulation
The globe structure allows controlled opening and closing.
- Reduced contamination risk
The lining separates process fluids from metal surfaces.
Applications in Chemical and Petrochemical Systems
PTFE lined globe valves are used where corrosive fluids require accurate flow control.
| Industry | Application | Common Media |
|---|---|---|
| Chemical processing | Transfer pipelines | Acids, solvents |
| Petrochemical | Process systems | Chemical mixtures |
| Pharmaceutical | Fluid handling | Cleaning solutions |
| Water treatment | Dosing systems | Chemical solutions |
PTFE vs PFA Lining Selection
PTFE and PFA are fluoropolymer materials with different performance characteristics.
| Material | Characteristics | Application |
| PTFE | Wide chemical compatibility | General corrosive fluids |
| PFA | Lower permeability and higher temperature capability | Demanding chemical service |
| Metal | High mechanical strength | Non-corrosive fluids |
A ptfe lined globe valve meets many chemical processing requirements. A pfa lined globe valve may be selected when lower permeation and higher temperature performance are needed.
Factors for Selecting a Lined Globe Valve
The correct valve material should match the pipeline conditions.
Important factors include:
- Chemical compatibility
The lining should resist the fluid composition and concentration.
- Temperature range
The valve material should match the operating temperature.
- Pressure rating
The valve should meet system pressure requirements.
Installation Guidelines for PTFE Lined Valves
Proper installation protects the lining layer and maintains sealing performance.
Recommended steps:
- Inspect the lining before installation.
- Confirm pipeline alignment and connection conditions.
- Avoid impact damage during handling.
- Check sealing parts during maintenance.
Incorrect installation may damage the lining and reduce valve performance.
FAQ About PTFE Lined Globe Valve
Where are PTFE lined globe valves used?
They are used in chemical, petrochemical, pharmaceutical, and water treatment systems with corrosive fluids.
Why choose a fluoropolymer lined globe valve?
It reduces chemical contact with metal components and supports reliable flow control.
What is the difference between PTFE and PFA lining?
PTFE provides broad chemical resistance, while PFA offers lower permeability and improved performance in some high-temperature applications.
Improving Chemical Pipeline Performance Through Valve Selection
Valve selection affects corrosion protection, maintenance requirements, and process stability. For chemical systems requiring both shutoff and adjustment, a properly selected lined globe valve provides reliable fluid control while protecting equipment from aggressive media.
FVF PTFE Lined Globe Valve
- FVF Lined globe valve is fully lined with fluorine materials.It has good anti-corrosive function and it is a better choice to shut-off in corrove pipeline.
- Globe valve refers to the valve with disc driven by stem along the central axis to make lifting movement, is a common block valve,used to connect or throttle medium.
- It has the advantage of compact structure, flexible on-off, strong corrosion resistance, trip shorted and widely applicated in chemical, petroleum, pharmaceutical, food, metallurgy, paper, hydropower, environment protection etc.
Product Parameter
Materials of Main Parts
| No. | Part Name | Material List | ||
| 1 | Body/Bonnet | HT250 | WCB | CF8 |
| 2 | Disc/Stem | 35 | 1Cr13 | 1Cr18Ni19 |
| 3 | Lining/Seat | PCTFE(F3) PTFE(F4) FEP(F46) PFA PO | ||
| 4 | Packing | PTFE(F4) | ||
| 5 | Packing Gland | WCB | WCB | CF8 |
| 6 | Handwheel | HT200 | HT200 | WCC |
Technical Specification
| Design & Manufacture Standard | GB/T 12233 | BS 5160 | ||
| Face-to-face Dimension Standard | GB/T 12221 | BS 5160 | ||
| Flange Standard | HG/T 20592 | ASME B16.5 | ||
| Inspection and Test Standard | GB/T 13927 | API 598 | ||
| Nominal Pressure | 1.0MPa | 1.6Mpa | 150LB | |
| Test Pressure | Shell Test | 1.5MPa | 1.5MPa | 1.5MPa |
| High Pressure Sealing | 1.1MPa | 1.1MPa | 1.1MPa | |
| Low Pressure Sealing | 0.6MPa | 0.6MPa | 0.6MPa | |
| Temperature Range | PFA:-29℃~200℃ PTFE:-29℃~180℃ FEP:-29℃~150℃ | |||
| Applicable Medium | Strong corrosive medium i.e.hydrochloric acid,Nitric acid,Hydrofluoric acid,Liquid chlorine,Sulfuric acid and Aqua regia etc. | |||
| Note:Test standard refers to general valve standard,high pressure should be customized for processing. | ||||
Get A Quote
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.