Pfa Teflon Lined Globe Control Valve

Place of Origin:
Wenzhou,China
Packing:
Suitable Packing for Sea/Air Transport
Connection:
Flange
Pressure:
PN10,PN16,150LBS
Temperature:
-29℃ ~180℃

A lined control valve regulates corrosive fluid processing through an impenetrable fluoropolymer barrier shielding metallic pressure cavities. In single-seat configurations, direct throttling occurs across an anchored polymer plug and orifice, eliminating galvanic attack and stress corrosion cracking across hydrochloric acid, spent pickle liquor, and nitric mixtures. This direct seat arrangement ensures tight closure while stabilizing volumetric discharge during continuous chemical processing.

Mechanical Shell Rigidity And Vacuum Anchorage

Ductile iron castings supply outer pressure boundaries capable of absorbing piping stresses and mechanical vibration. Precision dovetail machining locks the internal sleeve against cast surfaces, ensuring lined control valves resist liner detachment or deformation under severe suction drops and full vacuum conditions. Rigid metallic walls preserve structural dimensions when pipelines experience thermal expansion.

Engineering Characteristics Across Fluoropolymer Resins

Polymer Grade Service Temperature Tensile Limit Chemical Immersion
Virgin PTFE -20°C to 180°C 14 to 28 MPa Nitric, hydrofluoric, strong oxidizers
Melt PFA -30°C to 200°C 15 to 30 MPa Chlor-alkali, boiling aqua regia
Fluorinated Ethylene Propylene -40°C to 150°C 12 to 22 MPa Spent pickling acids, salt solutions

Thermal Permeation Resistance And Smooth Flow Geometries

Elevated operating temperatures often drive corrosive vapors through standard elastomeric compounds. Specifying a pfa lined control valve stops micro-porosity formation, blistering, and delamination across severe thermal loops reaching two hundred degrees Celsius, ensuring chemical purity during solvent recovery cycles.

Non-Stick Slurry Throttling And Hermetic Stem Containment

Chemical circuits bearing crystallizing salts demand smooth wetted surfaces to prevent particulate build-up. An extruded FEP liner provides non-stick contours that lower fluid drag and minimize actuator torque requirements.

Dynamic stem packing experiences abrasive friction during continuous modulation. Integrating a multi-ply virgin PTFE bellows creates a hermetic seal against fugitive emissions, maintaining ANSI FCI 70-2 Class VI shutoff compliance. Specifying a teflon lined globe control valve delivers smooth internal passages that resist slurry accumulation and prevent seat galling.

Pneumatic Actuation Response And Cavitation Defense

Multi-spring pneumatic diaphragm actuators coupled with digital positioners establish equal-percentage or linear flow profiles with minimal hysteresis. Direct throttle modulation stabilizes the flow coefficient across fluctuating pressure drops, suppressing cavitation damage and extending service intervals across automated distributed control circuits.

Product Parameter

Materials of Main Parts

No. Part Name Material List
1 Body/Bonnet WCB CF8 CF8M CF3 CF3M
2 Disc/Stem 1Cr13 1Cr18Ni9 00Cr17Ni4Mo2 1Cr18Ni9 00Cr17Ni4Mo2
3 Lining/Seat FEP     PTFE      PFA      PO
4 Packing PTFE
5 Packing Gland WCB CF8 CF8M CF3 CF3M

Technical Specification

Seat diameter (mm) 20 25 25 32 32 40 40 50 50 65 65 80 80 100 100 110 125 150 175
Rated Cv 5 10 10 16 16 24 24 44 44 68 68 125 125 165 165 195 330 360 460
Rated travel 16mm 25mm 38mm 50mm 60mm
Actual pressure Maxmum 1.0 MPa (1.6 MPa customised)
Nominal pressure I.0MPa, 1.6MPa
Working temperature -29°C-180°C
Trim Single seat plunger valve core
Flow characteristic Linear, equal percentage
Adjustable range 50:1
Equipped with ZJHA/B Multi-springs Diaphragm Pneumatic Actuators
Model ZJHA/B-22 ZJHA/B-23 ZJHA/B-34 ZJHA/B-45
Action mode ZJHA type actuator refer to "air-to-close" action: ZJHB actuator refer to "air-to-open" action
Pressure supply According to the scope of spring: 0.02-0.10, 0.04-0.20, 0.08-0.24 Mpa. Respectly are 0.14, 0.25, 0.35 MPa
Air supply connection Rc1/4
Basic error Without positioner:±5%; With posilioner:±1%;
Backlash Without positioner: 3%; With positioner: 1%;
Dead zone Without positioner: 3%; With positioner: 0.4%;
End point deviation Without positioner: opening point±2.5%, terminal point±5%;closing point±5%, terminal point±2.5%. With positioner error from beginning to end is ±1%;
Travel deviation ±2.5%
Leakage rate No more than 10 of rated CV
Optional accessories positioner, air set, solenoid valve, limit switch etc. (according to the order)

Get A Quote