Electric Actuator Ptfe Teflon Lined Gate Valve
- Place of Origin:
- Wenzhou,China
- Packing:
- Suitable Packing for Sea/Air Transport
- Connection:
- Flange
- Pressure:
- PN10,PN16,150LBS
- Temperature:
- PTFE:-29℃ ~180℃, PFA:-29℃~200℃, FEP:-29℃~150℃
Integrating motorized actuation with a lined gate valve requires calibrated limit switches to prevent mechanical crushing of resilient fluoropolymer seating faces. Electric multi-turn actuators generate immense axial thrust that can permanently deform soft polymeric wedges if seated solely through motor torque cutouts. Utilizing precision optical encoders or stroke-dependent limit switches halts travel exactly at full compression, delivering bubble-tight isolation across corrosive chemical pipelines without damaging the liner.
Signal Modulation and Explosion-Proof Enclosure Standards
Operating a ptfe lined gate valve in volatile chemical processing units demands fail-safe electrical architecture. Motorized actuators house synchronous electric motors, solid-state reversing starters, and 4-20 mA positioning cards within explosion-proof aluminum housings certified to ATEX and IECEx standards.
Digital positioners process continuous analog commands, regulating automated open-close cycling with zero signal latency. Internal anti-condensation space heaters protect internal circuitry against moisture ingress and ambient acid vapor corrosion during plant shutdowns.
Actuator Power Specifications and Chemical Service Envelope
| Operational Parameter | Standard AC Configuration | DC Emergency Backup | Fieldbus Network Mode |
|---|---|---|---|
| Supply Voltage | 380V / 460V Three-Phase | 24V Direct Current | 110V / 230V Single-Phase |
| Motor Duty Rating | S2 15 Minute Short-Time | S4 Intermittent Periodic | Continuous S9 Modulation |
| Enclosure Protection | IP68 Submersible | NEMA 7 Explosion-Proof | IECEx Flameproof Ex d |
| Control Protocol | Hardwired 4-20 mA | Dry Contact Relay | Profibus DP / Modbus RTU |
ISO 5211 Direct Mounting and Anti-Extrusion Stem Guidance
Standardized ISO 5211 mounting flanges couple electric drive sleeves directly to valve bonnets, eliminating angular misalignment and premature stem packing wear. Inside a teflon lined gate valve, dynamic stem loads concentrate along the rotating drive shaft during motorized actuation.
Reinforced stainless steel guide bearings prevent lateral stem deflection, keeping upward and downward movement perpendicular to the horizontal flow path. Dual chevron packing stacks flanking an intermediate lantern ring vent port ensure absolute fugitive emission containment during continuous motorized cycling.
Mechanical Travel Stops and EN 15714-2 Endurance Verification
Factory qualification verifies that motorized assemblies withstand rigorous thermal and mechanical stresses prior to field commissioning. Actuator travel undergoes calibration in accordance with EN 15714-2 endurance standards, completing thousands of full-stroke cycles under maximum differential pressure.
Submerged gas pressure testing verifies zero shell leakage, while electric torque sensor calibration confirms that seating thrust remains within safe elastic limits for PFA, FEP, and fluorocarbon barriers.
Product Parameter
Materials of Main Parts
| No. | Part Name | Material List | |||
| 1 | Body | HT250 | WCB | CF8 | CF8M |
| 2 | Bonnet | HT250 | WCB | CF8 | CF8M |
| 3 | Disc | HT250 | WCB | CF8 | CF8M |
| 4 | Lining/Seat | PCTFE(F3) PVDF(F4) FEP(F46) PFA PO | |||
| 5 | Packing | PTFE | |||
| 6 | Bracket | HT250 | WCB | CF8 | CF8 |
| 7 | Handwheel | QT400-15 | |||
Technical Specification
| Design & Manufacture Standard | GB/T 12234 | API 600 | ||
| Face-to-face Dimension Standard | GB/T 12221 | ASME B16.10 | ||
| Flange Standard | HG20592 | ASME B16.5 | ||
| Inspection and Test Standard | GB/T 13927 | API 598 | ||
| Nominal Pressure | 1.0MPa | 1.6Mpa | 150LB | |
| Test Pressure | Shell Test | 1.5MPa | 1.5MPa | 1.5MPa |
| High Pressure Sealing | 1.1MPa | 1.1MPa | 1.1MPa | |
| Low Pressure Sealing | 0.6MPa | 0.6MPa | 0.6MPa | |
| Temperature Range | PFA:-29℃~200℃ PTFE:-29℃~180℃ FEP:-29℃~150℃ | |||
| Applicable Medium | Strong corrosive medium i.e.hydrochloric acid,Nitric acid,Hydrofluoric acid,Liquid chlorine,Sulfuric acid and Aqua regia etc. | |||
| Note:Test standard refers to general valve standard,high pressure should be customized for processing. | ||||
Get A Quote
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.