Ptfe Pfa Lined Globe Valves

Place of Origin:
Wenzhou,China
Packing:
Suitable Packing for Sea/Air Transport
Connection:
Flange
Pressure:
PN10,PN16,150LBS
Temperature:
PTFE:-29℃ ~180℃, PFA:-29℃~200℃, FEP:-29℃~150℃

A lined globe valve isolates aggressive chemical streams from pressure-retaining metallic shells while delivering linear flow regulation and shutoff. This design combines a fluoropolymer inner lining with a rising-stem trim to achieve ANSI FCI 70-2 Class VI bubble-tight sealing inside piping systems handling concentrated sulfuric acid, hydrochloric acid, and chlorine gas. Plant operators replace costly exotic alloy valves with this assembly to resist pitting and uniform corrosion.

Flow Throttling and Cavitation Mitigation Mechanics

Internal geometry routes process media through an S-shaped flow path, translating linear plug displacement into exact equal percentage or linear flow characteristics. When dosing harsh reagents, a ptfe lined globe valve prevents wall erosion through balanced velocity dissipation across the valve seat. Thick compression-molded resin absorbs fluid turbulence and prevents localized cavitation erosion near the vena contracta during continuous micro-throttling service.

Fluoropolymer Protective Lining Specifications

Resin Type Operating Temperature Limit Vacuum Capability Target Chemical Exposure
Compression PTFE -20°C to +180°C Partial vacuum (-0.5 bar) Aqueous acids, standard alkalis
Transfer-Molded PFA -20°C to +200°C Full vacuum (0.1 mbar) Concentrated nitric acid, halogen gases
Melt-Extruded FEP -20°C to +150°C Positive pressure service Spent pickling liquors, diluted wash streams

Stem Containment and Mechanical Liner Anchoring

Stem leakage introduces severe toxic exposure risks during acid transfer. A pfa lined globe valve eliminates stem escape paths using multi-convolution fluoropolymer bellows assemblies backed with chevron packing sets. Machined dovetail grooves inside the cast ductile body lock the resin firmly against the wall. This mechanical retention stops liner collapse under severe thermal cycling and deep line vacuums.

Pneumatic Control Loop Integration and Dynamic Response

Automated chemical neutralization loops require repeatable valve travel. Integrating pfa lined globe valves with pneumatic diaphragm actuators provides immediate stroking response and fail-safe closing upon instrument air loss. Direct yoke mounting attaches digital positioners to the rising stem, eliminating mechanical linkage hysteresis. Continuous signal feedback maintains seat tightness and stable chemical dosing throughout demanding processing campaigns.

Product Parameter

Materials of Main Parts

No. Part Name Material List
1 Body/Bonnet HT250 WCB CF8
2 Disc/Stem 35 1Cr13 1Cr18Ni19
3 Lining/Seat PCTFE(F3)     PTFE(F4)    FEP(F46)     PFA      PO
4 Packing PTFE(F4)
5 Packing Gland WCB WCB CF8
6 Handwheel HT200 HT200 WCC

Technical Specification

Design & Manufacture Standard GB/T 12233 BS 5160
Face-to-face Dimension Standard GB/T 12221 BS 5160
Flange Standard HG/T 20592 ASME B16.5
Inspection and Test Standard GB/T 13927 API 598
Nominal Pressure 1.0MPa 1.6Mpa 150LB
Test Pressure Shell Test 1.5MPa 1.5MPa 1.5MPa
High Pressure Sealing 1.1MPa 1.1MPa 1.1MPa
Low Pressure Sealing 0.6MPa 0.6MPa 0.6MPa
Temperature Range PFA:-29℃~200℃    PTFE:-29℃~180℃  FEP:-29℃~150℃
Applicable Medium Strong corrosive medium i.e.hydrochloric acid,Nitric acid,Hydrofluoric acid,Liquid chlorine,Sulfuric acid and Aqua regia etc.
Note:Test standard refers to general valve standard,high pressure should be customized for processing.