Pfa Teflon Lined Globe Control Valve

Place of Origin:
Wenzhou,China
Packing:
Suitable Packing for Sea/Air Transport
Connection:
Flange
Pressure:
PN10,PN16,150LBS
Temperature:
-29℃ ~180℃

A lined control valve regulates aggressive chemical flows through an impervious fluoropolymer shield encasing metallic pressure boundaries. Single-port seating prevents galvanic attack, seat deflection, and nitric acid erosion while maintaining tight volumetric shutoff. Ductile iron casings absorb vibration, while machined interior dovetail slots hold thick polymer liners firmly against casing surfaces to eliminate vacuum collapse under sudden suction drops.

Thermal Permeation Control In Severe Process Circuits

Elevated temperatures accelerate molecular diffusion across generic polymeric barriers, creating blistering and substrate corrosion. Installing a pfa lined control valve prevents micro-porosity formation across continuous thermal cycles up to two hundred degrees Celsius.

High-density resin compounding ensures smooth interior surfaces that suppress particle collection in high-purity solvent lines. Uniform wall thickness along contoured internal flow paths stops acid pooling and minimizes pressure drops across high-velocity transfer loops.

Physical Limits Across Industrial Fluoropolymer Resins

Polymer Resin Continuous Thermal Threshold Tensile Rupture Limit Aggressive Chemical Immersion
Virgin PTFE -20°C to 180°C 14 to 28 MPa Concentrated nitric and sulfuric acids
Melt PFA -30°C to 200°C 15 to 30 MPa Boiling aqua regia, chlor-alkali streams
Extruded FEP -40°C to 150°C 12 to 22 MPa Spent pickling baths, dilute halogens

Zero Fugitive Emissions Through Bellows Containment

Dynamic stem packing experiences friction wear during frequent stroke cycles, creating emission paths for hazardous fumes. A multi-ply virgin PTFE bellows creates a hermetic seal around the moving stem, maintaining ANSI FCI 70-2 Class VI shutoff compliance.

Specifying a teflon lined globe control valve delivers streamlined fluid paths that prevent salt sedimentation and reduce seat galling. Secondary reinforced safety packing rings provide fail-safe containment if line pressure spikes exceed design thresholds.

Pneumatic Diaphragm Modulation And Flow Characterization

Direct coupling with multi-spring pneumatic diaphragm actuators and digital positioners yields linear or equal-percentage flow profiles with minimal hysteresis. Direct throttle control allows lined control valves to maintain uniform flow coefficient stability across erratic pressure drops, suppressing cavitation wear and extending service intervals throughout automated processing units.

Calibrated spring ranges deliver positive seating force, preventing internal backflow during sudden plant utility shutdowns.

Product Parameter

Materials of Main Parts

No. Part Name Material List
1 Body/Bonnet WCB CF8 CF8M CF3 CF3M
2 Disc/Stem 1Cr13 1Cr18Ni9 00Cr17Ni4Mo2 1Cr18Ni9 00Cr17Ni4Mo2
3 Lining/Seat FEP     PTFE      PFA      PO
4 Packing PTFE
5 Packing Gland WCB CF8 CF8M CF3 CF3M

Technical Specification

Seat diameter (mm) 20 25 25 32 32 40 40 50 50 65 65 80 80 100 100 110 125 150 175
Rated Cv 5 10 10 16 16 24 24 44 44 68 68 125 125 165 165 195 330 360 460
Rated travel 16mm 25mm 38mm 50mm 60mm
Actual pressure Maxmum 1.0 MPa (1.6 MPa customised)
Nominal pressure I.0MPa, 1.6MPa
Working temperature -29°C-180°C
Trim Single seat plunger valve core
Flow characteristic Linear, equal percentage
Adjustable range 50:1
Equipped with ZJHA/B Multi-springs Diaphragm Pneumatic Actuators
Model ZJHA/B-22 ZJHA/B-23 ZJHA/B-34 ZJHA/B-45
Action mode ZJHA type actuator refer to "air-to-close" action: ZJHB actuator refer to "air-to-open" action
Pressure supply According to the scope of spring: 0.02-0.10, 0.04-0.20, 0.08-0.24 Mpa. Respectly are 0.14, 0.25, 0.35 MPa
Air supply connection Rc1/4
Basic error Without positioner:±5%; With posilioner:±1%;
Backlash Without positioner: 3%; With positioner: 1%;
Dead zone Without positioner: 3%; With positioner: 0.4%;
End point deviation Without positioner: opening point±2.5%, terminal point±5%;closing point±5%, terminal point±2.5%. With positioner error from beginning to end is ±1%;
Travel deviation ±2.5%
Leakage rate No more than 10 of rated CV
Optional accessories positioner, air set, solenoid valve, limit switch etc. (according to the order)