Pneumatic Teflon Pfa Globe Lined Control Valve

Place of Origin:
Wenzhou,China
Packing:
Suitable Packing for Sea/Air Transport
Connection:
Flange
Pressure:
PN10,PN16,150LBS
Temperature:
-29℃ ~180℃

A lined control valve preserves internal conduit geometry under severe negative pressure through mechanical locking grooves machined directly into the metallic pressure boundary. When condensation or rapid upstream pump shutdowns generate deep vacuum states, unbonded fluoropolymer liners risk inward collapse across high-velocity throttling zones. Interlocking casting channels secure polymer walls against inward radial suction, maintaining precise fluid regulation across continuous chemical distillation loops.

Radial Suction Mitigation And Mechanical Dovetail Retention

Sub-atmospheric distillation columns generate intense pressure differentials between atmospheric air and internal process channels. Without continuous mechanical anchoring, radial suction pulls flexible fluoropolymers away from outer ductile iron bodies, causing severe flow restriction and stem binding.

Precision-machined T-slots and dovetail grooves cast into lined control valves lock thick polymer jackets firmly against casting surfaces, resisting delamination under transient vacuum spikes exceeding ninety-eight kilopascals.

Vacuum Endurance Parameters Across Operating Thermal Regimes

Process Operating Pressure Working Temperature Limit Minimum Liner Gauge Mechanical Retention Geometry
Full Vacuum (0.01 bar a) 120°C limit 3.5 mm thickness Symmetrical dovetail undercut
Partial Vacuum (0.40 bar a) 160°C limit 4.0 mm thickness Continuous radial locking T-slots
Atmospheric Throttling (1.0 bar a) 200°C limit 4.5 mm thickness Heavy-gauge knurled body cavity

High-Temperature Vacuum Resistance And Melt Flow Homogeneity

Elevated process temperatures soften fluoroplastic jackets, lowering tensile yield strength and increasing vulnerability to suction deformation. Deploying a pfa lined control valve preserves structural rigidity at temperatures reaching two hundred degrees Celsius, utilizing high molecular weight melt-processability to eliminate pinholes and micro-separations.

Uniform transfer molding forces molten resin deep into anchoring recesses, preventing vacuum delamination even when handling boiling nitric or hydrochloric acid slurries.

Reversing Pressure Gradient Control And Single-Seat Stability

Negative downstream pressures alter standard throttling forces, pulling valve plugs toward seats during low-flow regulation. Selecting a teflon lined globe control valve provides rigid internal support that prevents flow flutter and seat damage during sudden vacuum release events.

Direct actuator coupling maintains calibrated stroke positioning against reversing pressure gradients, securing reliable flow modulation across aggressive chemical recovery systems.

Product Parameter

Materials of Main Parts

No. Part Name Material List
1 Body/Bonnet WCB CF8 CF8M CF3 CF3M
2 Disc/Stem 1Cr13 1Cr18Ni9 00Cr17Ni4Mo2 1Cr18Ni9 00Cr17Ni4Mo2
3 Lining/Seat FEP     PTFE      PFA      PO
4 Packing PTFE
5 Packing Gland WCB CF8 CF8M CF3 CF3M

Technical Specification

Seat diameter (mm) 20 25 25 32 32 40 40 50 50 65 65 80 80 100 100 110 125 150 175
Rated Cv 5 10 10 16 16 24 24 44 44 68 68 125 125 165 165 195 330 360 460
Rated travel 16mm 25mm 38mm 50mm 60mm
Actual pressure Maxmum 1.0 MPa (1.6 MPa customised)
Nominal pressure I.0MPa, 1.6MPa
Working temperature -29°C-180°C
Trim Single seat plunger valve core
Flow characteristic Linear, equal percentage
Adjustable range 50:1
Equipped with ZJHA/B Multi-springs Diaphragm Pneumatic Actuators
Model ZJHA/B-22 ZJHA/B-23 ZJHA/B-34 ZJHA/B-45
Action mode ZJHA type actuator refer to "air-to-close" action: ZJHB actuator refer to "air-to-open" action
Pressure supply According to the scope of spring: 0.02-0.10, 0.04-0.20, 0.08-0.24 Mpa. Respectly are 0.14, 0.25, 0.35 MPa
Air supply connection Rc1/4
Basic error Without positioner:±5%; With posilioner:±1%;
Backlash Without positioner: 3%; With positioner: 1%;
Dead zone Without positioner: 3%; With positioner: 0.4%;
End point deviation Without positioner: opening point±2.5%, terminal point±5%;closing point±5%, terminal point±2.5%. With positioner error from beginning to end is ±1%;
Travel deviation ±2.5%
Leakage rate No more than 10 of rated CV
Optional accessories positioner, air set, solenoid valve, limit switch etc. (according to the order)